Reducer/Expander effect on PSV? - Safety Relief Valve engineering (PSV) (2024)

  • Home
  • Forums
  • People
  • Chemical Engineers
  • Safety Relief Valve engineering (PSV)
  • Thread starteripocoyo
  • Start dateNov 13, 2018
Status
Not open for further replies.
  • Nov 13, 2018
  • #1

ipocoyo

Mechanical
Apr 17, 2016
40

My current D orifice PSV has an inlet size of 20mm. If I were to attach a 8mm reducer to the inlet, what effects does it have on the PSV in terms of its set pressure, flow capacity etc?

Thanks in advance!

Replies continue below

Recommended for you

Sort by dateSort by votes

  • Nov 14, 2018
  • #2

RVAmeche

Mechanical
Jan 20, 2015
796

PSV inlet piping cannot be any smaller than the inlet connection of the device. So if you have a 20 mm inlet connection, all inlet piping needs to be at least 20 mm. Furthermore, the total inlet losses cannot exceed 3% of the set pressure at rated capacity.

Upvote0Downvote

  • Nov 14, 2018
  • Thread starter
  • #3

ipocoyo

Mechanical
Apr 17, 2016
40

Is there a reason for this? Are there any references for it?

Upvote0Downvote

  • Nov 14, 2018
    1
  • #5

RVAmeche

Mechanical
Jan 20, 2015
796

The PSV has a defined flow rate. Reducing the area of the piping will either result in a large pressure drop between the vessel/system and device at the flow capacity, or the device will not be able to reach it's flow capacity. API 520 and ASME both spell this requirement out.

3% losses is the general standard to prevent chatter. Basically the when closed the system pressure rises; once the valve begins to open the pressure seen at the valve drops below its set pressure due to the high losses of the piping and the valve re-closes. Since the system pressure is still high, the valve keeps opening and closing and destroys itself.

Upvote0Downvote

  • Nov 14, 2018
  • Thread starter
  • #6

ipocoyo

Mechanical
Apr 17, 2016
40

Thank you all. I did not realise there as a second part to API 520.

Upvote0Downvote

  • Nov 14, 2018
  • #7

RVAmeche

Mechanical
Jan 20, 2015
796

I'd highly recommend you have a seasoned engineer review your relief valve calculations and design. It's not something to be rubber stamped

Upvote0Downvote

  • Nov 15, 2018
  • Thread starter
  • #8

ipocoyo

Mechanical
Apr 17, 2016
40

Just going through api 520 clause 7.3.2 and I have another question.

Since the excessive pressure loss will cause chattering and hence, lower the capacity of the PSV and quite possible cause damage to the seating surface, will the PSV still be able to relieve excess pressure in the event of an over pressurisation?

Upvote0Downvote

  • Nov 16, 2018
  • #9

e43u8

Chemical
Feb 23, 2008
134

PSV might still be, more or less, able to relieve excessive pressure in an over pressure case; but its seating surface damage may cause having continuous leakage through the PSV even in normal case...

Upvote0Downvote

  • Nov 16, 2018
  • #10

RVAmeche

Mechanical
Jan 20, 2015
796

The PSV may still operate but could leak due to seal damage like e43 mentioned. However if we're still talking about an 8mm pipe for a 20mm inlet PSV, it's very likely you won't get the flow capacity. The system pressure would likely need to go much higher than your allowable overpressure to result in the PSV reaching it's flow capacity since your 8mm pipe will have significant losses.

Upvote0Downvote

  • Nov 16, 2018
  • #11

don1980

Chemical
May 3, 2007
669

Seat damage is a trivial matter, and a risk that's generally tolerable. Note that every metal seated PSV has a high risk of leakage after activation, due to seat damage. Chatter is a concern because it risks: (1) insufficient relieving capacity, and (2) loss-of-containment due to mechanical failure of the installation. The flowrate through a chattering valve is only a fraction of the valve's rated capacity, and this will cause the system pressure to rise. In most cases an equilibrium will be reached, at which point the PSV operates in a stable manner, albeit at an pressure that's probably greater than the allowable accumulation. The risk of loss of containment, due to mechanical failure, is much higher for PSVs in liquid service. That's because the force of impact, which occurs during each open-close cycle, is much greater in a incomprssible fluid service. Loss of containment can occur with a chattering PSV in incompressible fluid service, but the risk isn't as great.

To minimize the risk of chatter, most design codes require the inlet pipe (x-sec area) to be at least as large as the PSV inlet connection. In this particular case (8mm pipe leading to a 20mm PSV inlet), the restriction is severe. That's not a good design. It's a code noncompliance, and most likely it's an significant safety risk.

Upvote0Downvote

Status
Not open for further replies.

Similar threads

  • Locked
  • Question

PSV Discharge Orientation1

  • Henry S
  • May 22, 2024
  • Safety Relief Valve engineering (PSV)
Replies
12
Views
639

May 23, 2024

LittleInch

  • Locked
  • Question

Bench testing of Pilot PSV2

  • Mohammad Saad
  • Jun 10, 2024
  • Safety Relief Valve engineering (PSV)
Replies
3
Views
399

Jun 11, 2024

Mohammad Saad

  • Locked
  • Question

PSV relief pressure and set pressure2

  • rika kose
  • Jul 8, 2024
  • Safety Relief Valve engineering (PSV)
Replies
14
Views
635

Jul 11, 2024

rika kose

  • Locked
  • Question

Guidance on selecting a Pressure Safety Valve (PSV) from API 526 "Valve Size" column1

  • samuel-1
  • Jul 19, 2024
  • Safety Relief Valve engineering (PSV)
Replies
4
Views
491

Jul 20, 2024

georgeverghese

  • Locked
  • Question

Rupture disk downstream of a PSV piping system

  • SNagri
  • Aug 12, 2024
  • Safety Relief Valve engineering (PSV)
Replies
11
Views
584

Aug 18, 2024

horacio Torres

Part and Inventory Search

Sponsor

  • Home
  • Forums
  • People
  • Chemical Engineers
  • Safety Relief Valve engineering (PSV)
Reducer/Expander effect on PSV? - Safety Relief Valve engineering (PSV) (2024)
Top Articles
Latest Posts
Recommended Articles
Article information

Author: Trent Wehner

Last Updated:

Views: 6321

Rating: 4.6 / 5 (76 voted)

Reviews: 83% of readers found this page helpful

Author information

Name: Trent Wehner

Birthday: 1993-03-14

Address: 872 Kevin Squares, New Codyville, AK 01785-0416

Phone: +18698800304764

Job: Senior Farming Developer

Hobby: Paintball, Calligraphy, Hunting, Flying disc, Lapidary, Rafting, Inline skating

Introduction: My name is Trent Wehner, I am a talented, brainy, zealous, light, funny, gleaming, attractive person who loves writing and wants to share my knowledge and understanding with you.